Home / Water and wastewater Water and wastewater

See the pump that will fail in the next storm.

Your SCADA already records flow, amps, level and run hours at every station. Artekis reads them every hour against each pump’s own earlier runs, so a pump that is wearing shows up while it still runs and still passes. These findings are from a wastewater plant running Artekis: six lift stations and a treatment plant. The pump, turbidity and alarm findings are open on the plant today; the ragging and stuck-level findings are from earlier runs on the same plant.

The evidence

What the finding shows

Pump 1 now moves 12% less water for the same powerFlow per amp of LS-4 Pump 1, median per day of its runsHigher is better. A healthy pump holds a flat line: Pump 2, its twin, is unchanged (within 1%). Artekis found this by reading back through the plant’s past data on the day it was set up.
4244464850Water moved per amp of motor current (gpm/A)Oct 12Oct 16Oct 20Oct 24Oct 28Nov 1Nov 5Oct 11: 49.8 gpm per ampOct 12: 49.7 gpm per ampOct 13: 49.6 gpm per ampOct 14: 49.1 gpm per ampOct 15: 49.0 gpm per ampOct 16: 48.7 gpm per ampOct 17: 48.5 gpm per ampOct 18: 48.1 gpm per ampOct 19: 47.9 gpm per ampOct 20: 47.7 gpm per ampOct 21: 47.3 gpm per ampOct 22: 47.1 gpm per ampOct 23: 46.7 gpm per ampOct 24: 46.4 gpm per ampOct 25: 46.2 gpm per ampOct 26: 45.9 gpm per ampOct 27: 45.6 gpm per ampOct 28: 45.3 gpm per ampOct 29: 44.9 gpm per ampOct 30: 44.5 gpm per ampOct 31: 44.1 gpm per ampNov 1: 43.8 gpm per ampNov 2: 43.6 gpm per ampNov 3: 43.5 gpm per ampNov 4: 43.5 gpm per ampNov 5: 43.6 gpm per ampNov 6: 43.6 gpm per ampNov 7: 43.6 gpm per ampNov 8: 43.7 gpm per ampNormal: about 320 gpm at 6.5 A (its runs of Sep 24 to Oct 19)12% less waterabout 280 gpm now, for the same 6.5 ANo alarm is set on this reading.Artekis catches it here: Oct 224244464850Water moved per amp (gpm/A)Oct 12Oct 21Oct 30Nov 8Oct 11: 49.8 gpm per ampOct 12: 49.7 gpm per ampOct 13: 49.6 gpm per ampOct 14: 49.1 gpm per ampOct 15: 49.0 gpm per ampOct 16: 48.7 gpm per ampOct 17: 48.5 gpm per ampOct 18: 48.1 gpm per ampOct 19: 47.9 gpm per ampOct 20: 47.7 gpm per ampOct 21: 47.3 gpm per ampOct 22: 47.1 gpm per ampOct 23: 46.7 gpm per ampOct 24: 46.4 gpm per ampOct 25: 46.2 gpm per ampOct 26: 45.9 gpm per ampOct 27: 45.6 gpm per ampOct 28: 45.3 gpm per ampOct 29: 44.9 gpm per ampOct 30: 44.5 gpm per ampOct 31: 44.1 gpm per ampNov 1: 43.8 gpm per ampNov 2: 43.6 gpm per ampNov 3: 43.5 gpm per ampNov 4: 43.5 gpm per ampNov 5: 43.6 gpm per ampNov 6: 43.6 gpm per ampNov 7: 43.6 gpm per ampNov 8: 43.7 gpm per ampNormal: 320 gpm at 6.5 A12% lesswaterNo alarmset on thisCaught Oct 22

Chart redrawn from the finding as Artekis showed it on Nov 9, 2026. Open the real finding

The treated water got cloudier and stayed that way, with no alarmFinal effluent turbidity, 12-hour mediansLower is better: turbidity is how cloudy the treated water is. It read about 1.55 NTU for weeks. Artekis found this by reading back through the plant’s past data on the day it was set up.
1234Treated water turbidity (NTU). Lower is clearer.Oct 12Oct 16Oct 20Oct 24Oct 28Nov 1Nov 5Oct 11: 1.57 NTUOct 12: 1.56 NTUOct 12: 1.56 NTUOct 13: 1.56 NTUOct 13: 1.56 NTUOct 14: 1.55 NTUOct 14: 1.55 NTUOct 15: 1.55 NTUOct 15: 1.55 NTUOct 16: 1.55 NTUOct 16: 1.55 NTUOct 17: 1.54 NTUOct 17: 1.55 NTUOct 18: 1.55 NTUOct 18: 1.55 NTUOct 19: 1.55 NTUOct 19: 1.55 NTUOct 20: 1.55 NTUOct 20: 1.56 NTUOct 21: 1.55 NTUOct 21: 1.55 NTUOct 22: 1.55 NTUOct 22: 1.55 NTUOct 23: 1.55 NTUOct 23: 1.55 NTUOct 24: 1.71 NTUOct 24: 1.57 NTUOct 25: 1.55 NTUOct 25: 1.55 NTUOct 26: 1.55 NTUOct 26: 1.55 NTUOct 27: 1.55 NTUOct 27: 1.55 NTUOct 28: 1.55 NTUOct 28: 1.56 NTUOct 29: 1.56 NTUOct 29: 1.68 NTUOct 30: 2.08 NTUOct 30: 1.98 NTUOct 31: 2.06 NTUOct 31: 2.29 NTUNov 1: 2.36 NTUNov 1: 2.52 NTUNov 2: 2.66 NTUNov 2: 2.88 NTUNov 3: 3.58 NTUNov 3: 3.29 NTUNov 4: 3.31 NTUNov 4: 3.37 NTUNov 5: 3.39 NTUNov 5: 3.42 NTUNov 6: 3.44 NTUNov 6: 3.45 NTUNov 7: 3.43 NTUNov 7: 3.43 NTUNov 8: 3.42 NTUNormal: about 1.55 NTUNo alarm is set on this reading.About 1.8 NTU above normal1.55 then, about 3.4 nowArtekis catches it here: Oct 30, at 2.1 NTU1234Turbidity (NTU)Oct 12Oct 21Oct 30Nov 8Oct 11: 1.57 NTUOct 12: 1.56 NTUOct 12: 1.56 NTUOct 13: 1.56 NTUOct 13: 1.56 NTUOct 14: 1.55 NTUOct 14: 1.55 NTUOct 15: 1.55 NTUOct 15: 1.55 NTUOct 16: 1.55 NTUOct 16: 1.55 NTUOct 17: 1.54 NTUOct 17: 1.55 NTUOct 18: 1.55 NTUOct 18: 1.55 NTUOct 19: 1.55 NTUOct 19: 1.55 NTUOct 20: 1.55 NTUOct 20: 1.56 NTUOct 21: 1.55 NTUOct 21: 1.55 NTUOct 22: 1.55 NTUOct 22: 1.55 NTUOct 23: 1.55 NTUOct 23: 1.55 NTUOct 24: 1.71 NTUOct 24: 1.57 NTUOct 25: 1.55 NTUOct 25: 1.55 NTUOct 26: 1.55 NTUOct 26: 1.55 NTUOct 27: 1.55 NTUOct 27: 1.55 NTUOct 28: 1.55 NTUOct 28: 1.56 NTUOct 29: 1.56 NTUOct 29: 1.68 NTUOct 30: 2.08 NTUOct 30: 1.98 NTUOct 31: 2.06 NTUOct 31: 2.29 NTUNov 1: 2.36 NTUNov 1: 2.52 NTUNov 2: 2.66 NTUNov 2: 2.88 NTUNov 3: 3.58 NTUNov 3: 3.29 NTUNov 4: 3.31 NTUNov 4: 3.37 NTUNov 5: 3.39 NTUNov 5: 3.42 NTUNov 6: 3.44 NTUNov 6: 3.45 NTUNov 7: 3.43 NTUNov 7: 3.43 NTUNov 8: 3.42 NTUNormal: about 1.55 NTUNo alarm set on this reading1.8 NTUabove normalCaught Oct 30

Chart redrawn from the finding as Artekis showed it on Nov 9, 2026. Open the real finding

Why it matters: EPA estimates at least 23,000 to 75,000 sanitary sewer overflows a year in the US.Source: US EPA, Sanitary Sewer Overflows

Open the wastewater plant yourself

Millbrook Creek Utility District runs Artekis around the clock: six lift stations and a treatment plant. It opens on the Artekis findings list. Pick the lift station 4 pump finding to see its evidence. No sign-in, on a computer or a phone.

Open the plant →